Skip to content

1102: Network Topology Design

⏱ 9 min read·📅 Last updated: 2026-10-17

Difficulty: ⭐ Beginner

Estimated Time: 2 hours

Abstract

The physical and logical layout of your network determines how well the AI lab performs under load. This document explains why a star topology is the default for small labs, how to select a switch, how to segment an AI lab into VLANs, and how to plan subnets and names so the network stays legible as it grows.


Table of Contents


1. Overview

1.1 Purpose

Before a single VM boots, decide how devices connect and how traffic flows. A deliberate topology prevents the two most common small-lab failure modes: daisy-chained devices that collapse under load, and a single flat network where a noisy training job starves the management interface.

1.2 Prerequisites

Learning Objectives

After completing this document, you will be able to:

  • Justify star topology over daisy-chain or mesh-at-home alternatives
  • Choose a switch using concrete criteria
  • Design a VLAN plan for management, storage, compute, and serving traffic
  • Allocate IPs in a way that survives growth
  • Configure VLANs on a generic managed switch

2. Why Star Topology

In a star topology every device connects to a central switch:

                    +-------------------------------------+
                    |        Managed Switch (hub)         |
                    |                                     |
                    |  Port 1:  WAN/router uplink         |
                    |  Port 2:  Hypervisor / GPU server   |
                    |  Port 3:  Storage server (optional) |
                    |  Port 4:  Workstation               |
                    |  Port 5+: Expansion                 |
                    +-----------------+-------------------+
                                      |
              +-----------------------+-----------------------+
              |                       |                       |
              v                       v                       v
        +----------+           +----------+            +----------+
        |  Server  |           | Storage  |            | Clients  |
        +----------+           +----------+            +----------+

2.1 Comparison with Alternatives

Property Star Daisy-chain Wi-Fi mesh
Any-to-any hop count 2 (device-switch-device) Up to N 2-4 (via nodes)
Failure isolation One cable affects one device A dead mid-chain link splits the network Variable
Deterministic latency Yes No (grows with chain depth) No
Throughput under load Full line rate per port Shared along the chain Radio-bound
Cabling effort One cable per device Minimal None

The decisive property for AI workloads is deterministic bandwidth between storage and GPU nodes. Moving an 11 GB model file over NFS while training logs stream to the same storage server is exactly the traffic pattern star topology handles and chains do not.


3. Switch Selection

You do not need exotic hardware. Evaluate any switch against this table:

Criterion Minimum When it matters
Port speed 1 Gbps all ports Baseline; fine for a single-GPU lab
Multi-gig / 2.5G+ ports Optional Useful if your NICs support it and NFS transfers are slow
10G uplink/SFP+ Optional Storage-heavy labs, multi-node clusters
Managed (VLANs) Required for VLAN section Unmanaged switches cannot create or assign VLANs (all ports effectively sit in VLAN 1)
Jumbo frame support (MTU 9216) Recommended Pairs with 1103
Backplane capacity >= 2x sum of all port speeds (full duplex) Prevents blocking under full load
Fanless or quiet Nice to have Labs usually live in living spaces

Selection guidance:

  • Two-node lab (server + workstation): any unmanaged 1G switch works.
  • Lab with NAS or multi-GPU server: managed switch with VLAN support; multi-gig ports optional.
  • Multi-node training: managed switch, jumbo frames, and consider 10G on storage uplinks.

LACP (link aggregation) is a vendor-neutral way to add bandwidth between switch and storage server: two or four 1G ports behave as one logical link. It raises aggregate throughput but not single-stream speed.


4. VLAN Segmentation for AI Labs

VLANs split one physical switch into isolated logical networks. The value for an AI lab: management traffic stays reachable when a training run saturates the network, and serving traffic cannot reach the hypervisor's admin UI.

4.1 Example VLAN Plan

VLAN ID Name Carries Example Subnet
10 Management Hypervisor UI, switch/AP admin, BMC/IPMI 192.168.10.0/24
20 Storage NFS, iSCSI, backup traffic 192.168.20.0/24
30 GPU Compute Node-to-node training traffic, cluster overlay 192.168.30.0/24
40 Inference Serving APIs, ingress from users 192.168.40.0/24
50 Workstations (optional) Personal devices, internet clients 192.168.50.0/24

4.2 Design Rules

  1. Management VLAN is the most protected. Only admin workstations get routed access to it.
  2. Storage VLAN is the most private. It often has no gateway at all - if it cannot reach the internet, it cannot be attacked from it.
  3. Compute and inference can be separate, so a batch-training broadcast storm never touches user-facing latency. On a two-node lab, a single combined VLAN is an acceptable simplification.
  4. Inter-VLAN routing happens on the router/firewall (or a Layer-3 switch), with explicit allow rules only.

5. Subnet and IP Planning

Pick one subnet per VLAN and reserve ranges by role so that an IP address tells you what a machine is. The example below uses 192.168.1.0/24 for a flat (single-VLAN) starter lab; scale the pattern to the per-VLAN subnets above as you grow.

5.1 Example Allocation (192.168.1.0/24)

Range Role Assignment method
192.168.1.1 Router/gateway Static
192.168.1.2-9 Network gear (switch, APs) Static
192.168.1.10 Hypervisor / primary server Static (example used throughout this course)
192.168.1.50 GPU worker / second node Static
192.168.1.100 NAS / storage server (optional) Static
192.168.1.150-199 Workstations DHCP reservation
192.168.1.200-254 Guest/DHCP pool Dynamic

5.2 Why Bother

  • Static addresses for servers mean firewall rules, NFS exports, and K3s node configs never rot after a reboot.
  • Role-based ranges make grep 192.168.1. in a config file immediately interpretable.
  • Document the table in your repo (this file is the template); an undocumented static IP is a future outage.

6. Naming Conventions

Names should encode function, not brand or purchase date:

Pattern:  <role><index>.<domain>

academy-gw1      - gateway/router
academy-sw1      - switch 1
academy-hv1      - hypervisor node 1 (example: 192.168.1.10)
academy-gpu1     - GPU worker node (example: 192.168.1.50)
academy-nas      - storage server (example: 192.168.1.100)
academy-ws1      - workstation

Rules of thumb:

  • Lowercase, hyphen-separated, DNS-safe (K3s and NFS both embed hostnames in configs).
  • Role first so tab-completion and kubectl get nodes group meaningfully.
  • Keep the search domain short (academy.local or your own domain) and use it consistently for cluster-internal DNS.

7. Basic Switch Configuration

The CLI dialect varies by vendor (Cisco-style, NETGEAR, MikroTik, ProCurve...), but the concepts are identical. The example below is a Cisco-like generic dialect:

! 1. Define the VLANs
vlan 10
  name MGMT
vlan 20
  name STORAGE
vlan 30
  name GPU-COMPUTE
vlan 40
  name INFERENCE

! 2. Trunk port to the server (carries multiple VLANs, 802.1Q tagged)
interface gi1/0/2
  description academy-hv1
  switchport mode trunk
  switchport trunk allowed vlan 10,20,30,40
  mtu 9216

! 3. Access port to a plain client (one untagged VLAN)
interface gi1/0/4
  description workstation
  switchport mode access
  switchport access vlan 50
  mtu 9216

! 4. Trunk to the router (inter-VLAN routing lives here)
interface gi1/0/1
  description uplink-to-router
  switchport mode trunk
  switchport trunk allowed vlan 10,20,30,40,50

On the Linux side (hypervisor or server), tagged VLANs are created as subinterfaces:

# /etc/network/interfaces (Debian/Proxmox style) - VLAN 20 for storage
auto eno1.20
iface eno1.20 inet static
    address 192.168.20.10/24
    vlan-raw-device eno1

Verify from a connected host:

ping -c 3 192.168.20.10     # storage VLAN reachable

# Confirm the subinterface is tagged with VLAN 20 (world-readable, no sudo needed):
grep VID /proc/net/vlan/eno1.20        # expect: VID: 20

8. Cabling

Copper Ethernet categories set the ceiling:

Cable 1 Gbps 2.5/5G Multi-Gig 10 Gbps Notes
Cat5e 100 m 2.5G at 100 m; 5G needs Cat6 Not rated Adequate for most starter labs
Cat6 100 m Supported Up to ~55 m Common sweet spot
Cat6a 100 m Supported 100 m Required for 10G across a room

Practical rules:

  • Buy pre-terminated cables; field-crimped ends are the top source of intermittent CRC errors.
  • Avoid running copper parallel to power cables for long runs; cross at 90 degrees.
  • Label both ends (a label maker pays for itself the first time you re-cable at midnight).
  • Fiber (DAC or SFP+) only matters at 10G+ distances; not needed in a starter lab.

9. Troubleshooting

9.1 Common Issues

Symptom Likely Cause Fix
Device unreachable after VLAN change Port still in access mode on old VLAN Set trunk + allowed VLAN list (Section 7)
VLAN-tagged host gets no DHCP No DHCP relay/helper on that VLAN Add ip helper-address <router> or run DHCP per-VLAN
Intermittent slowdowns on one port Bad cable / CRC errors Replace cable; check port error counters
Can reach storage VLAN from workstation Missing inter-VLAN ACL Add deny rule on router between VLAN 50 and VLAN 20
Switch reboots under load Power budget exceeded (PoE models) Check PoE draw vs budget
Everything works until jumbo frames enabled One hop has MTU 1500 Walk the path with ping -M do -s 8972 (see 1103)

9.2 Diagnostic Commands

# Port error counters (CRC, collisions) - most switches expose via CLI:
show interfaces counters errors

# Verify which VLAN a port carries:
show interfaces gi1/0/2 switchport

# From a Linux host: confirm the interface is up and tagged correctly:
ip -d link show eno1.20

10. Summary

  • Star topology (everything to one switch) is the correct default: deterministic latency, isolated failures, easy growth.
  • Switch selection: managed + VLAN support is the one hard requirement; port speed beyond 1G is optional.
  • Segment by traffic type (management / storage / compute / inference) so load and blast radius stay contained.
  • Plan IP ranges by role and document them; static IPs for anything with a firewall rule or NFS export.
  • Cat5e is enough for 1G; Cat6a covers 10G. Label your cables.

Case Study: A 2.5G Apartment Star Network

The original build ran a 16-port 2.5G managed switch through a small apartment with three zones - the generic star above with real port assignments:

             +--------------------------------------------+
             |        2.5G managed switch (star hub)      |
             |  P1 WAN (ONT)        P5-8 office/lab       |
             |  P2-4 living room    P9 NAS      P10 NUC   |
             |  P11-16 expansion                          |
             +---------------------+----------------------+
                                   |
         +-------------------------+-------------------------+
         |                         |                         |
   living room                office                    server
   AP, media, IoT             workstation, lab PC       NAS, NUC (Proxmox)

Packet flows that justified the design:

Flow Path Why it matters
Model transfer NAS -> NUC NAS LAN3 (P9) -> switch -> NUC (P10) < 0.5 ms, jumbo frames (MTU 9000) on both ends
Internet -> all devices ONT (P1) -> switch -> everywhere NAT/DHCP on the router behind bridge mode (see 1101)
NUC -> eGPU Not a network path PCIe tunnel over Thunderbolt 3, ~32 Gbps - the switch never sees it

VLAN plan the build actually used (different roles than the lesson table - a home needs an IoT quarantine):

VLAN Name Carries
10 Management Switch, APs, NAS admin
20 IoT Smart devices, isolated from everything else
30 Servers Proxmox, K3s nodes
40 Workstations PC, NUC desktop clients
50 Guest Internet-only, fully isolated

Real-world 2.5G throughput:

Protocol Theoretical Measured Efficiency
TCP (IPv4) 2.5 Gbps 2.3-2.4 Gbps 92-96%
SMB (Windows) 2.5 Gbps 2.2-2.3 Gbps 88-92%
NFS (Linux) 2.5 Gbps 2.3-2.4 Gbps 92-96%

QoS and flow control. The switch queued by priority: SSH/VoIP highest, cluster API and storage I/O next, general traffic, bulk backup last. 802.3x flow control stayed enabled so a saturated NFS stream degraded instead of dropping packets.

LACP in practice. The NAS aggregated LAN1+LAN2+LAN3 into one LAG: 7.5 Gbps theoretical, about 6 Gbps real-world for parallel streams - and no improvement for a single NFS stream, exactly the caveat Section 3 makes.

Monitoring. SNMP on the switch (snmpwalk -v2c -c public <switch-ip> IF-MIB::ifHCInOctets from the NAS), with periodic checks of per-port CRC errors, discards, and pause frames - the counters that catch cabling problems before users do.


References


Next Steps


Related Documents:

Case Study Experiment: EXP_1102: Star Topology and Network Performance Experiments - hands-on topology and throughput experiments from the original build


Document ID: 1102

Status: Complete

Related Documents: [1103, 1201]